• Model

    A 6 VSA

  • Marka

    TRANSCOM

  • A 6 VSA
  • Frequency range: 1MHz to 6000MHz
  • Signal demodulation: FM, LTE, (AM, GSM, WCDMA, and NB-IoT signal in the future)
  • DANL: -166 dBm @1GHz (Sensitivity set to High, normalized to 1Hz)
  • Resolution bandwidth: 10Hz to 5MHz
  • Signal storage depth of 1Gbit for signal capture and analysis
  • API library is provided for secondary development

Product features

  • Compact size and easy to carry
  • Excellent performance indexes
  • Support communication mode and IOT signal analog output
  • Wide power adjusting range
  • Multiple controlling modes with simplified interface

Typical applications

  • Signal demodulation
  • Laboratory RF test
  • System integration
  • Production test
  • Teaching demonstration
Signal demodulation
  • A6 can do GSM, WCDMA and LTE signal demodulation.
  • FM/AM demodulation are supported.
  • NB-IoT signal demodulation is also supported.
General test in laboratory, factory, school, etc.
  • General spectrum analysis
  • Display in waterfall plot rage power output
  • Easy installation and set-up
Ürün 4-6 hafta içerisinde teslim edilebilir.
Stokta Yok
  • En iyi Fiyat
  • Müşteri Memnuniyeti
  • Yüksek Kalite
  • Destek
  • Yeni Gelen Ürünler
Birim Fiyat 0,00 TL + KDV
Havale İndirimli 0,00 TL + KDV

Function

Sensitivity

Low, Medium and High

Demodulator

Digital signals, FM, and LTE (AM, GSM, WCDMA, and NB-IoT will be supported in the future)

Frequency

Frequency Range

1MHz to 6GHz

Frequenc Reference

Aging rate: ±1ppm

Frequency
Readout Accuracy

±( (readout frequency + 1GHz) x Frequency
Reference + Frequency Span Accuracy x Span)

Frequency Span Accuracy

±1%

Sweep Time

1.2ms to 1600s

3.99ms to 1600s, zero span

Resolution bandwidth

RBW Range

10Hz to 5MHz, (1-2-3-5-10 Sequence)

RBW Accuracy

RBW≥1MHz,±10%

RBW<1MHz, ±2%

Amplitude

Measuring Range

Display Average Noise Level to +20dBm

Input Attenuator Range

0 to 30dB, 1dB Step

Maximum Safe Input Level

Sensitivity: +30dBm (Low)

Sensitivity: 0dBm (Medium)

Sensitivity: -20dBm (High)

Reference Level Range

-140 dBm to +20dBm

-190dBm to +70dBm (Ref level offset: ON)

Amplitude Accuracy

ATT set to 0dB, Input Signal: -5 to -30 dBm; Detector set to Positive; Sensitivity set to
Low; RBW Auto-Coupled, all other settings Auto-Coupled, 23±5℃

Half hour warm-up required.

±1.5dB

RBW Switching Uncertainty

±0.3dB

Input Attenuator Uncertainty

±0.6dB

Accuracy of Reference Level

Reference level: ≥-60dBm, ±0.8dB

Display Average Noise Level (DANL) @1GHz

Input
Terminated, Detector set to Positive, Trace Average set to 1000, Span set to
50kHz, Ref set to -100dBm, all other settings auto-coupled, 23±5 ℃.

Normalized to 1 Hz RBW

Sensitivity: Low

-129dBm/Hz (typically -132dBm/Hz)

Sensitivity: Medium

-149dBm/Hz (typically -152dBm/Hz)

Sensitivity: High

-166dBm/Hz (typically -168dBm/Hz)

Residual Response

-75dBm

Input-Related Response

10MHz to 1.1GHz

<-70dBc

1.1GHz to 1.85GHz, 2.9GHz to 2.97GHz

<-41dBc

1.85GHz to 2.9GHz, 2.97GHz to 3.11GHz, 3.7GHz to 5.6GHz

<-50dBc

5.2GHz to 5.8GHz

<-45dBc

3.11GHz to 3.7GHz, 5.6GHz to 6.0GHz 

<-39dBc

Second Harmonic Distortion

1.6GHz -70dBc

Third-Order Intercept (TOI)

-10dBm tones, 1MHz apart, Sensitivity set to low, Ref set to -10 dBm

+15dBm

P1dB

+5dBm (nominal)

Phase Noise @1GHz

-95dBc/Hz, @10kHz (typically -98dBc/Hz)

-115dBc/Hz, @1MHz (typically -120dBc/Hz)

Storage

Maximum storage depth

1Gbit

Data format

I/Q two-way, 16bit

Bandwidth

2.5Mz, 5MHz, 10MHz, 20MHz

 

General

 

OS

Windows Xp, Windows7, Windows 8 and Windows 10

Connectors

RF Input: N-type, female, 50Ω

USB: USB type C

Power interface: DC12V

Operating Environment

Operating temperature: 0°C to 50°C

Storage temperature: -20°C to 70°C

Dimension

180mm×50mm×290mm

Weight

1.8kg

Technical specifications

 

This technical specifications include the influence of probability distribution, measurement uncertainty and environmental factors on the instrument performance. It guarantees the performance under the following conditions.

  • The instrument is ON and warmed up for 30 min
  • The instrument internal reference signal is applied

Testing temperature is 23±5 ºC, unless other specific condition applied.

 

Typical value

 

Additional description does not cover all performance information of the product guarantee. Unless otherwise specified, the typical value refers to the indicator or technical specification with which more than 80% of products comply under 23 ± 5 ºC. The measurement uncertainty is excluded. A6 should be within the calibration period.

Nominal value

 

The nominal value refers to the characteristic description or design range. It is not tested or covered by the product. A6 should be within the calibration period.

AXESS
2 Taksit3 Taksit4 Taksit5 Taksit6 Taksit
0,00 X 2 = 0,000,00 X 3 = 0,000,00 X 4 = 0,000,00 X 5 = 0,000,00 X 6 = 0,00
BONUS
2 Taksit3 Taksit4 Taksit5 Taksit6 Taksit
0,00 X 2 = 0,000,00 X 3 = 0,000,00 X 4 = 0,000,00 X 5 = 0,000,00 X 6 = 0,00
CARDFINANS
2 Taksit3 Taksit4 Taksit5 Taksit6 Taksit
0,00 X 2 = 0,000,00 X 3 = 0,000,00 X 4 = 0,000,00 X 5 = 0,000,00 X 6 = 0,00
MAXIMUM
2 Taksit3 Taksit4 Taksit5 Taksit6 Taksit
0,00 X 2 = 0,000,00 X 3 = 0,000,00 X 4 = 0,000,00 X 5 = 0,000,00 X 6 = 0,00
PARAF
2 Taksit3 Taksit4 Taksit5 Taksit6 Taksit
0,00 X 2 = 0,000,00 X 3 = 0,000,00 X 4 = 0,000,00 X 5 = 0,000,00 X 6 = 0,00
WORLD
2 Taksit3 Taksit4 Taksit5 Taksit6 Taksit
0,00 X 2 = 0,000,00 X 3 = 0,000,00 X 4 = 0,000,00 X 5 = 0,000,00 X 6 = 0,00
İletişim
ÇINAR MAH 5003 SK. 2/2 713 BORNOVA / İZMİR
0 537 828 18 09
yavuz@brotechelectronic.com
E-Bültene Kayıt Ol
Copyright 2019 Brotechelectronic.Tüm Hakları Saklıdır Web Tasarım Teknobay